Exclusion of complications of central venous catheters: Ultrasound versus X-ray

##plugins.themes.academic_pro.article.main##

Mahmoud Marzouk
Oussama Nasri
Rabeb Hammami
Chadha Ben Messaoud
Saber Thamlaoui
Nader Baffoun
Olfa Kaabachi
Chokri Kaddour

Abstract

Introduction: The placement of central venous catheters (CVC) is a frequent procedure in intensive care. It is not devoid of complications, the diagnosis of which relied for a long time on the chest X-ray. Currently, ultrasound appears to be an interesting alternative.


Aim : To report the impact of the use of ultrasound on the time to exclusion of mechanical complications after CVC placement.


Methods : This is a prospective, multicenter, comparative, double-blind study. Were included the patients in whom the placement of a CVC was decided. After placement, a chest X-ray was ordered and an ultrasound was performed to look for signs of misplacement and pneumothorax. The two examinations were interpreted by two different doctors. The primary endpoint between the ultrasound group and the RTX group was the time “T1” represented by the time required to exclude complications.


Results : 30 patients were included in our study. The mean ultrasound T1time was significantly lower than the mean radiological T1time (p=0.000). Only one case of pneumothorax was observed. It was first detected by ultrasound. For the 29 other patients, exclusion of pneumothorax was confirmed by ultrasound and chest X-ray. No misplacement type complications detected. This was confirmed by ultrasound and radiological exclusions.


Conclusion : Ultrasound is a faster tool than RTX in excluding mechanical complications after CVC placement. It guarantees a non-irradiating examination as efficient as chest X-ray for intensive care patients.

Keywords:

Central venous catheters, ultrasonography, pneumothorax, complications, thoracic radiography

##plugins.themes.academic_pro.article.details##

References

  1. Raman D, Sharma M, Moghekar A, Wang X, Hatipoğlu U. Utilization of Thoracic Ultrasound for Confirmation of Central Venous Catheter Placement and Exclusion of Pneumothorax: A Novel Technique in Real-Time Application. Journal of Intensive Care Medicine.2019;34(7):594‑8.
  2. Eisenmann S, Winantea J, Karpf-Wissel R, Funke F, Stenzel E, Taube C, et al. Thoracic ultrasound for immediate exclusion of pneumothorax after interventional bronchoscopy. Journal of Clinical Medicine.2020;9(5).
  3. Koh JS, Chung C, Kim JO, Jung SS, Park HS, Lee JE, et al. Early detection of delayed pneumothorax using lung ultrasound after transthoracic needle lung biopsy: A prospective pilot study. Clinical Respiratory Journal.2022;16(5):413‑9.
  4. Smit JM, Haaksma ME, Lim EHT, Steenvoorden TS, Blans MJ, Bosch FH, et al. Ultrasound to detect central venous catheter placement associated complications: A multicenter diagnostic accuracy study. Anesthesiology. 2020;781‑94.
  5. Rowan KR, Kirkpatrick AW, Liu D, Forkheim KE, Mayo JR, Nicolaou S. Traumatic pneumothorax detectionwiththoracic US: Correlationwithchestradiography and CT - Initial experience. Radiology.2002;225(1):210‑4.
  6. Wilkerson RG, Stone MB. Sensitivity of bedsideultrasound and supine anteroposterior chest radiographs for the identification of pneumothorax after blunt trauma. Academic Emergency Medicine.2010;17(1):11‑7
  7. Chan KK, Joo DA, McRae AD, Takwoingi Y, Premji ZA, Lang E, et al. Chest ultrasonography versus supine chest radiography for diagnosis of pneumothorax in trauma patients in the emergency department. Cochrane Database of Systematic Reviews.2020;2020(7)
  8. Bhoil R, Kumar R, Kaur J, Attri PK, Thakur R. Diagnosis of traumatic pneumothorax-comparison between lung ultrasound and supine chest radiographs. Indian Journal of Critical Care Medicine. 2021;25(2):176‑80.
  9. Hosseini-Nik H, Bayanati H, Souza CA, Gupta A, McInnes MDF, Pena E, et al. Limited Chest Ultrasound to Replace CXR in Diagnosis of Pneumothorax Post Image-Guided Transthoracic Interventions. Canadian Association of Radiologists Journal.2022;73(2):403‑9.
  10. Ramos Hernández C, Delgado MN, Rial MB, Roibás CM, Leiro Fernández V, Pombo V, et al. Revista Clínica Española Validity of lung ultrasound to rule out iatrogenic pneumothorax performed by pulmonologists without experience in this procedure. Vol. 221, Revista Clínica Española. 2021 p. 258‑63.
  11. Mirabile C, Malekzadeh-Milani S, Vinh TQ, Haydar A. Intraoperative hypoxia secondary to pneumothorax: The role of lung ultrasound. Paediatric Anaesthesia.2018;28(5):468‑70.
  12. Furlong-Dillard J, Aljabari S, Hirshberg E. Diagnostic AccuracyAmongTrainees to Safely Confirm Peripherally Inserted Central Catheter (PICC) Placement Using Bedside Ultrasound CE. Journal of the Association for Vascular Access.2020;25(3):10‑7.
  13. Wakabayashi R. Availability of ultrasoundimaging of a guidewireparallel to the vein during internal jugular central venous catheter placement. Scientific Reports.2021;11(1).
  14. Trabelsi B, Hajjej Z, Drira D, Yedes A, Labbene I, Ferjani M, et al. Comparison of ultrasound-guided internal jugular vein and supraclavicular subclavian vein catheterization in critically ill patients: a prospective, randomized clinical trial. Ann Intensive Care . 2022;12(1).